JOB NAME:   LLDE - EduServ monthly FRS file archive



JOB PURPOSE:  This job copies the monthly EduServ FRS file to

	      archive tape for permanent retention.



JOB SUBMISSION:

     *Normal Run Frequency:   Once per month, whenever EduServ

     sends the University a month end version of C.U.'s FRS file.



     *Conflicts:  This job should NOT be run while LLIB (FRS

     Interface report) is running.



     *Dependencies:  Run LLIB (FRS Interface Report) after this

     job if scheduled on the same day/night.



     *Run Considerations:  This job creates an archive file

     of the EduServ monthly FRS file.  Any job run (including user

     Easytrieves) that reads file LAM.FRS.FREEZE.D&MONTH&YEAR

     will fail if it is run prior to correcting failed runs of LLDE.  

     This job must bring in the most recent non-labeled

     monthly FRS tape from Eduserv.



PROGRAM LIST:

     *IEBGENER - COPY EDUSERV FRS FILE TO ARCHIVE TAPE - LLDE#1



JOB SETUP:

     *Symbolic Parameters:

          MONTH - Month corresponding to month of EduServ supplied tape

          YEAR - Year corresponding to current calendar year

          VOLSER - Volume serial number from EduServ supplied tape

          PRTM1 - Dispatch parameters for reports



     *Control records:  None



FILES:

     *Input:

          (T)  EduServ supplied FRS tape (foreign tape)

               This file must be read BLP.



     *Output:

          (T)  LAM.FRS.FREEZE.D&MONTH&YEAR (archive of

               Eduserv FRS tape)



     *I/O:

          None



REPORTS:  None



PROGRAM NAME AND DESCRIPTION:

     *IEBGENER - Will return a condition code of 0000 upon

     		 successful copy of input tape.



VALIDATION PROCEDURE:

     *Check JCL messages for error condition return code.  Any

      code other than 0000 means the job failed.



RERUN INSTRUCTIONS:

     LLDE Step #                                    			 Program Name

              1   RERUN JOB                               		   IEBGENER

                  MESSAGE:  SEE UTILITIES MESSAGES MANUAL 

			    FOR IEBGENER ERROR MESSAGE

                  ACTION:   CORRECT ERROR AND RERUN JOB



CHANGE LOG:

     931020    New job (PN) SR6887